A、 The kernel has been tampered with.
B、 The Trusted Platform Module chip has failed.
C、 The administrator attempted to boot with a bootloader that is unsigned or has been tampered with.
D、 A package (VIB or driver) has been tampered with.
E、
F、
G、
H、
I、
J、
答案:A
解析:解析: The fatal error “Secure Boot Failed” may indicate that either the kernel or a package (VIB or driver) has been tampered with, which violates the Secure Boot integrity check.致命错误“安全引导失败”可能表示内核或软件包(VIB或驱动程序)已被篡改,这违反了安全引导完整性检查。
A、 The kernel has been tampered with.
B、 The Trusted Platform Module chip has failed.
C、 The administrator attempted to boot with a bootloader that is unsigned or has been tampered with.
D、 A package (VIB or driver) has been tampered with.
E、
F、
G、
H、
I、
J、
答案:A
解析:解析: The fatal error “Secure Boot Failed” may indicate that either the kernel or a package (VIB or driver) has been tampered with, which violates the Secure Boot integrity check.致命错误“安全引导失败”可能表示内核或软件包(VIB或驱动程序)已被篡改,这违反了安全引导完整性检查。
A. VSphere Distributed Services Engine
B. Data Processing Units (DPUs)
C. vSphere Network I/O Control
D. Universal Passthrough version 2
解析:解析: The solution that would help achieve better performance and near-zero CPU utilization from the ESXi hosts for networking functions and processing is Data Processing Units (DPUs), which are specialized processors that offload network services from the CPU and provide hardware acceleration.数据处理单元(dpu)是一种专门的处理器,可以从ESXi主机上获得更好的性能,并使网络功能和处理的CPU利用率接近于零,这种处理器可以从CPU上卸载网络服务,并提供硬件加速。
A. 50
B. 10
C. 25
D. 1
E.
F.
G.
H.
I.
J.
解析:解析: The minimum supported network throughput in Gb/s for each host in an all flash vSAN cluster based on the vSAN Original Storage Architecture (OSA) is 10. vSAN Express Storage Architecture (ESA) are only supported with 25Gbps and higher connection speeds. ESA ReadyNodes configured for vSAN ESA will be configured with 25/50/100Gbps NICs. vSAN OSA all-flash configurations are only supported with a 10Gb or higher connections. One reason for this is that the improved performance with an all-flash configuration may consume more network bandwidth between the hosts to gain higher throughput.在基于vSAN原始存储体系结构(OSA)的全闪存vSAN群集中,每个主机支持的最低网络吞吐量(Gb/s)为10。vSAN Express Storage Architecture(ESA)仅支持25Gbps和更高的连接速度。为vSAN配置的ESA读取节点ESA将配置25/50/100Gbps网卡。vSAN OSA全闪存配置仅支持10Gb或更高的连接。其中一个原因是,全闪存配置提高的性能可能会消耗主机之间更多的网络带宽来获得更高的吞吐量。
A. Add a minimum of three hosts with two uplinks each
B. Add a minimum of two hosts with two uplinks each
C. Add a minimum of three hosts with four uplinks ea/ch
D. Add a minimum of two hosts with one uplink each
A. 75 percent of the capacity over a 30 second period
B. 60 percent of the capacity over a 30 second period
C. 60 percent of the capacity over a 40 second period
D. 75 percent of the capacity over a 40 second period
解析:解析: The distributed switch calculates uplinks for virtual machines by taking their port ID and the number of uplinks in the NIC team. The distributed switch tests the uplinks every 30 seconds, and if their load exceeds 75 percent of usage, the port ID of the virtual machine with the highest I/O is moved to a different uplink. 分布式交换机通过获取虚拟机的端口ID和NIC组中的上行链路数量来计算虚拟机的上行链路。分布式交换机每30秒测试一次上行链路,如果其负载超过使用率的75 %,具有最高I/O的虚拟机的端口ID将被移至不同的上行链路。
A. Update all Tanzu Kubernetes Grid clusters to the latest version prior to the Supervisor cluster update.
B. No action is needed - Tanzu Kubernetes Grid clusters will be updated automatically as part of the update process.
C. No action is needed - Incompatible Tanzu Kubernetes Grid clusters can be manually updated after the Supervisor cluster update.
D. Update incompatible Tanzu Kubernetes Grid clusters prior to the Supervisor cluster update.
解析:解析:Option D is correct because it indicates that the administrator must update incompatible Tanzu Kubernetes Grid clusters prior to the Supervisor cluster update, as this will ensure that there are no compatibility issues or disruptions during or after the update process. Option A is incorrect because it is not necessary to update all Tanzu Kubernetes Grid clusters to the latest version prior to the Supervisor cluster update, as some clusters may already be compatible with the new version. Option B is incorrect because Tanzu Kubernetes Grid clusters will not be updated automatically as part of the update process, as they require manual intervention from the administrator. Option C is incorrect because incompatible Tanzu Kubernetes Grid clusters cannot be manually updated after the Supervisor cluster update, as they may become inaccessible or unstable due to compatibility issues.选项D是正确的,因为它表明管理员必须在管理集群更新之前更新不兼容的Tanzu Kubernetes网格集群,因为这将确保在更新过程中或之后没有兼容性问题或中断。选项A是不正确的,因为没有必要在管理集群更新之前将所有Tanzu Kubernetes网格集群更新到最新版本,因为一些集群可能已经与新版本兼容。选项B是不正确的,因为Tanzu Kubernetes网格集群不会在更新过程中自动更新,因为它们需要管理员的手动干预。选项C是不正确的,因为不兼容的Tanzu Kubernetes网格集群在管理集群更新之后不能被手动更新,因为它们可能由于兼容性问题而变得不可访问或不稳定。If a Tanzu Kubernetes Grid cluster is incompatible with vSphere 8, upgrade the cluster before proceeding with the system upgrade.如果Tanzu Kubernetes网格集群与vSphere 8不兼容,请在继续系统升级之前升级该集群。
A. vMotion networking
B. Management networking
C. vSAN networking
D. Virtual machine networking
E.
F.
G.
H.
I.
J.
解析:
A. A preferential rule between the DB group and PROD11 group
B. A preferential rule between the DB group and the PROD55 group
C. A preferential rule between the DB group and the PROD55 group
D. A required rule between the DB group and the PROD11 group
E.
F.
G.
H.
I.
J.
解析:解析:Option A is correct because it allows the administrator to create a preferential rule between the DB group and PROD11 group, which will force the VMs in the DB group to run on the hosts in the PROD11 group if possible, but will allow them to run on the hosts in PROD55 group if necessary. Option B is incorrect because it will create a preferential rule between the DB group and PROD55 group, which will force the VMs in the DB group to run on the hosts in PROD55 group if possible, which is not what the administrator wants. Option C is incorrect because it is the same as option B. Option D is incorrect because it will create a required rule between the DB group and PROD11 group, which will force the VMs in the DB group to run only on the hosts in PROD11 group and not allow them to run on the hosts in PROD55 group if needed.选项A是正确的,因为它允许管理员在DB组和PROD11组之间创建一个优先规则,如果可能,该规则将强制DB组中的虚拟机在PROD11组中的主机上运行,但如果必要,将允许它们在PROD55组中的主机上运行。选项B是不正确的,因为它将在数据库组和PROD55组之间创建一个优先规则,如果可能的话,将强制数据库组中的虚拟机在PROD55组中的主机上运行,这不是管理员想要的。选项C不正确,因为它与选项b相同。选项D不正确,因为它将在数据库组和PROD11组之间创建一个必需的规则,该规则将强制数据库组中的虚拟机仅在PROD11组中的主机上运行,而不允许它们在需要时在PROD55组中的主机上运行。
A. Datastore
B. Data center
C. Datastore cluster
D. Virtual machine
解析:解析: To create a custom alarm to notify when thin provisioning reaches a certain capacity threshold, the administrator must define this alarm at the datastore level, as it is related to datastore usage要创建自定义警报以在精简资源调配达到特定容量阈值时发出通知,管理员必须在数据存储区级别定义此警报,因为它与数据存储区使用情况相关
A. VMware vCenter
B. Standalone Velero and Restic
C. NSX-T Manager
D. vSphere Host Client
E. Velero Plugin for vSphere
F.
G.
H.
I.
J.
解析:
A. Attach the host profile to the new host
B. Duplicate the host profile
C. Copy the host settings from the new host
D. Import the host profile
解析:解析: The task that should be completed prior to checking the compliance with an existing host profile is to attach the host profile to the new host, which allows applying the configuration template of the reference host to the new host.在检查与现有主机配置文件的符合性之前,应该完成的任务是将主机配置文件附加到新主机,这允许将参考主机的配置模板应用到新主机。