APP下载
首页
>
IT互联网
>
虚拟化高级试题题库4
搜索
虚拟化高级试题题库4
题目内容
(
多选题
)
86.A VMware Service Provider is tasked with delivering a solution for continuous availability for a subset of Tier 1 virtual machines ( ) and vApps running in their vSAN environment. The VMs make up a missioncritical application and there can be no data loss in the event of an outage at their primary data center. In the event of a regional outage, they have established a 10-minute recovery point objective ( ). Failover/failback to the third site must be automated.
They have the following in place:
Two local data centers ( ) connected with 100 Gb dedicated fiber.
- 2ms round-trip time ( ) latency between the sites.

A、  Site Recovery Manager

B、  Snapshots

C、  vSAN Metro Cluster

D、  vSphere Data Protection

E、  vStorage APIs for Array Integration (VAAI)

答案:AC

虚拟化高级试题题库4
7.An architect is designing the expansion of an existing vSphere 7 environment. The customer is requesting a design for a new cluster to support the anticipated future business growth. The requirements specified for the existing environment design must be considered when designing the new cluster.
The existing design has the following requirements:
REQ01 The environment has an availability target of 99.5% for all infrastructure.
REQ02 The recovery time objective ( ) for Tier 1 virtual machines is one hour.
REQ03 Windows and Linux virtual machines must reside on separate clusters.
REQ04 Access to the management cluster within the environment must be controlled.
Which of the listed requirements would be classified as a functional requirement?
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722e-bff0-c0f9-29e3bb5dbe01.html
点击查看题目
74.The storage team at an organization is planning to migrate from an older Fibre Channel storage environment to a new environment using IP-based storage.
Which two switch features or characteristics are appropriate for IP storage networks? Choose two.
https://www.shititong.cn/cha-kan/shiti/0005ee2e-7230-0810-c0f9-29e3bb5dbe00.html
点击查看题目
76.A customer has a database cluster with 40/60 read/write ratio and a high IOPs requirement with no contention on an all-flash vSAN cluster.
Which two storage settings should be configured for best performance? Choose two.
https://www.shititong.cn/cha-kan/shiti/0005ee2e-7230-13c8-c0f9-29e3bb5dbe00.html
点击查看题目
38.Refer to the exhibit.
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-5c30-c0f9-29e3bb5dbe00.html
点击查看题目
51.An architect has 50 ESXi hosts to deploy and DHCP servers are not allowed on any network.
Which automated host deployment method should the architect use?
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-8b10-c0f9-29e3bb5dbe01.html
点击查看题目
12.Which design decision must be included in a design to allow for the deployment of a minimum supported configuration of vCenter High Availability ( )?
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722e-df30-c0f9-29e3bb5dbe00.html
点击查看题目
80.Which two statements are true about gathering functional business and application requirements? Choose two.
https://www.shititong.cn/cha-kan/shiti/0005ee2e-7230-2368-c0f9-29e3bb5dbe00.html
点击查看题目
13.A customer has six hosts available in a cluster. When running at full capacity, all virtual machines can be run on two hosts.
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722e-df30-c0f9-29e3bb5dbe01.html
点击查看题目
25.An architect is designing a new greenfield environment that will install ESXi on local disks. There is a requirement to streamline initial and future installations of ESXi hosts.
Which configuration option should the architect recommend for installing ESXi hosts to meet these requirements?
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-1db0-c0f9-29e3bb5dbe00.html
点击查看题目
36.A new vSphere platform is being created. The platform will host virtual machines that will run management services and line-of-business applications.
What should the architect consider when designing the number and type of clusters required?
https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-5460-c0f9-29e3bb5dbe01.html
点击查看题目
首页
>
IT互联网
>
虚拟化高级试题题库4
题目内容
(
多选题
)
手机预览
虚拟化高级试题题库4

86.A VMware Service Provider is tasked with delivering a solution for continuous availability for a subset of Tier 1 virtual machines ( ) and vApps running in their vSAN environment. The VMs make up a missioncritical application and there can be no data loss in the event of an outage at their primary data center. In the event of a regional outage, they have established a 10-minute recovery point objective ( ). Failover/failback to the third site must be automated.
They have the following in place:
Two local data centers ( ) connected with 100 Gb dedicated fiber.
- 2ms round-trip time ( ) latency between the sites.

A、  Site Recovery Manager

B、  Snapshots

C、  vSAN Metro Cluster

D、  vSphere Data Protection

E、  vStorage APIs for Array Integration (VAAI)

答案:AC

分享
虚拟化高级试题题库4
相关题目
7.An architect is designing the expansion of an existing vSphere 7 environment. The customer is requesting a design for a new cluster to support the anticipated future business growth. The requirements specified for the existing environment design must be considered when designing the new cluster.
The existing design has the following requirements:
REQ01 The environment has an availability target of 99.5% for all infrastructure.
REQ02 The recovery time objective ( ) for Tier 1 virtual machines is one hour.
REQ03 Windows and Linux virtual machines must reside on separate clusters.
REQ04 Access to the management cluster within the environment must be controlled.
Which of the listed requirements would be classified as a functional requirement?

A.   The environment has an availability target of 99.5% for all infrastructure

B.   The recovery time objective (RTO) for Tier 1 virtual machines is one hour

C.   Access to the management cluster within the environment must be controlled

D.   Windows and Linux virtual machines must reside on separate clusters

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722e-bff0-c0f9-29e3bb5dbe01.html
点击查看答案
74.The storage team at an organization is planning to migrate from an older Fibre Channel storage environment to a new environment using IP-based storage.
Which two switch features or characteristics are appropriate for IP storage networks? Choose two.

A.   Fabric extending devices

B.   Spanning Tree Protocol (STP)

C.   2:1 or greater bandwidth oversubscription for 10 GbE switches

D.   Non-blocking switch

E.   Deep or ultra buffered switches

https://www.shititong.cn/cha-kan/shiti/0005ee2e-7230-0810-c0f9-29e3bb5dbe00.html
点击查看答案
76.A customer has a database cluster with 40/60 read/write ratio and a high IOPs requirement with no contention on an all-flash vSAN cluster.
Which two storage settings should be configured for best performance? Choose two.

A.   IOPs limits enabled

B.   RAID 1

C.   Deduplication and Compression disabled

D.   RAID 5/6

E.   Deduplication and Compression enabled

https://www.shititong.cn/cha-kan/shiti/0005ee2e-7230-13c8-c0f9-29e3bb5dbe00.html
点击查看答案
38.Refer to the exhibit.

A.   Enable vSphere HA and add a VM Override with VM Restart Priority set to Disabled

B.   Enable Fault Tolerance

C.   Achieve application availability with snapshots

D.   Enable vSphere HA and add a VM Override with VM Restart Priority set to Lowest

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-5c30-c0f9-29e3bb5dbe00.html
点击查看答案
51.An architect has 50 ESXi hosts to deploy and DHCP servers are not allowed on any network.
Which automated host deployment method should the architect use?

A.   Stateless vSphere Auto Deploy

B.   Stateful vSphere Auto Deploy

C.   Scripted installation

D.   Interactive installation

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-8b10-c0f9-29e3bb5dbe01.html
点击查看答案
12.Which design decision must be included in a design to allow for the deployment of a minimum supported configuration of vCenter High Availability ( )?

A.   A new subnet will be provisioned for vCenter HA services

B.   A vSphere cluster will consist of more than three nodes

C.   The deployed vCenter Server will be Tiny

D.   The vCenter HA network will support a latency of less than 50 ms

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722e-df30-c0f9-29e3bb5dbe00.html
点击查看答案
80.Which two statements are true about gathering functional business and application requirements? Choose two.

A.   It focuses on functional requirements with C-level stakeholders

B.   It leverages a single set of questions for all stakeholders

C.   It might require multiple rounds of stakeholder interviews

D.   It builds stakeholder consensus

E.   It is a non-iterative process

https://www.shititong.cn/cha-kan/shiti/0005ee2e-7230-2368-c0f9-29e3bb5dbe00.html
点击查看答案
13.A customer has six hosts available in a cluster. When running at full capacity, all virtual machines can be run on two hosts.

A.   Two

B.   Three

C.   One

D.   None

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722e-df30-c0f9-29e3bb5dbe01.html
点击查看答案
25.An architect is designing a new greenfield environment that will install ESXi on local disks. There is a requirement to streamline initial and future installations of ESXi hosts.
Which configuration option should the architect recommend for installing ESXi hosts to meet these requirements?

A.   Installation with kick start script

B.   Auto Deploy with stateless caching mode

C.   Manual installation using boot from SAN

D.   Auto Deploy with stateful install mode

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-1db0-c0f9-29e3bb5dbe00.html
点击查看答案
36.A new vSphere platform is being created. The platform will host virtual machines that will run management services and line-of-business applications.
What should the architect consider when designing the number and type of clusters required?

A.   Maximum tolerable downtime

B.   Predicted platform growth

C.   Auditing requirements for the virtual machines

D.   The level of isolation required between virtual machine classifications

https://www.shititong.cn/cha-kan/shiti/0005ee2e-722f-5460-c0f9-29e3bb5dbe01.html
点击查看答案
试题通小程序
试题通app下载