A、 Date shall be managed as time fuel and distance to climb from sealevel versus outside air temperature altitude and weight
B、 Date shall be presented as time fuel and distance to climb from sealevel versus outside air temperature altitude and weight
C、 Date shall be presented as time fuel and distance to lift from sealevel versus outside air temperature altitude and weight
答案:B
A、 Date shall be managed as time fuel and distance to climb from sealevel versus outside air temperature altitude and weight
B、 Date shall be presented as time fuel and distance to climb from sealevel versus outside air temperature altitude and weight
C、 Date shall be presented as time fuel and distance to lift from sealevel versus outside air temperature altitude and weight
答案:B
A. If the engine appears to be heating, turn it off.
B. If the engine appears to be overheating, turn it off.
C. If you think the engine is too hot, turn the switch to off"'"
A. If an engine overheat/fire detector can not operate, the engine and APU fire alarm unit alternatively changes to single loop operation. In the single loop module, only one loop must check the engine and APU fire detection module for an overheat or fire condition to give the alarm condition.
B. If an engine overheat/fire detector fails to operate, the engine and APU fire detection module automatically changes to single loop operation. In the single loop mode, only one loop must detect an overheat or fire condition for the engine and APU fire detection module to give the alarm condition.
C. If an engine overheat/fire detector is inoperative, the engine and APU fire detection module automatically changes to single loop operation. In the single loop mode, only one loop must detect an overheat or fire condition by the engine and APU fire detection module for the alarm condition.
A. Make sure that the two valves at the lower of the unit engage.
B. Make sure that the two spigots at the base of the unit engage.
C. Make sure that the two spigots at the bottom of the unit engage.
A. Install the point tags on the negative overheat thermocouple of the turbine.
B. install the terminal tags on the forward overheat thermocouple of the turbine
C. Install the port tags on the rearward overheat thermocouple of the turbine.
A. Obey the following procedure if the manufacturer provides you different instructions
B. If the manufacturer instructs you differently, the following procedure should be ignored
C. If the man ufacturer's instructions are different from the following procedure, obey the following procedure
A. Catalyst remains unchanged during the processing of chemical action.
B. Catalyst is substance used to change the speed or rate of a chemical action with its molecular structure being changed.
C. Catalyst is substance used to change the speed or rate of a chemical action without being physically changed itself.
A. 拆卸密封胶和钝铁锹。
B. 用锋利的铲子去除密封胶。
C. 用钝刮刀刮掉密封胶。
A. 从海平面到温度为-56.5℃(-69.7℉).....
B. 从海平面到温度为-56.5℃(-69.7℉)的高度的温度梯度为每英尺-0.00198℃(-0.003564℉),高于该高度为零。
C. 从海平面到温度为-56.5℃(-69.7℉)...
A. 系统中向驾驶舱提供热空气的部分及其控制装置。包括冷凝器组件、燃油系统和控制、爆燃、与加热器操作相关的指示系统等,如适用。不包括温度控制和指示系统。
B. 系统中向座舱提供热空气的部分及其控制装置。包括加热器组件、滑油系统和控制、点火、与加热器操作相关的指示系统等,如适用。不包括制冷控制和指示系统。
C. 系统中向座舱提供热空气的部分及其控制装置。包括加热器组件、燃油系统和控制、点火、与加热器操作相关的指示系统等,如适用。不包括温度控制和指示系统。
A. Mix the bonding material with a spatula
B. Use the bonding material with a spatula
C. Put the bonding material with a spatula